    schedule 30 pipe dimensions, schedule 30 pvc pipe dimensions chart, schedule 30 pipe thickness in mm, 30 inch pipe schedule chart, schedule 30 pvc pipe wall thickness, schedule 30 steel pipe pressure rating, sch 30 steel pipe dimensions, sch 30 steel pipe price, sch 30 steel pipe weight chart

    Steel pipes come in various international grades and schedules, each defining their physical properties. Schedule 30 Steel Pipes are designed for low-pressure applications, offering a balance of strength and weight. These pipes are used in scenarios where only mild working pressures are required.The weight of Schedule 30 pipes varies between 0.32 kg and 351.7 kg per meter, depending on their dimensions, which range from 1.8 inches to 36 inches. The wall thickness of these pipes is specifically defined by their schedule, ensuring they meet the necessary standards for their intended use.

    According to the sch 30 pipe chart, a 3-inch pipe with an outside diameter of 88.9 mm and a wall thickness of 4.78 mm weighs 9.92 kg/m. In contrast, a 10-inch pipe with an outer diameter of 273 mm and a wall thickness of 7.8 mm weighs 51.03 kg/m. The pressure rating of Sch 30 pipes is determined by the combination of their wall thickness and diameter, with thicker walls and smaller diameters generally supporting higher pressure ratings.

    Schedule 30 steel pipes are designed for medium to low pressure applications. Although they have lower impact strength compared to higher schedule pipes, they are valued for their durability and are widely used in transferring water and gas. These pipes are also commonly employed in underground piping systems for towns and cities.

    Dimensions of Schedule 30 Steel Pipe

    Nominal size [inches] Outside diameter [inches] Outside diameter [mm] Wall thickness [inches] Wall thickness [mm] Weight [lb/ft] Weight [kg/m]
    1/8 inches 0.405 inches 10.3 MM 0.068 inches 1.73 MM 0.24 lb/ft 0.37 kg/m
    1/4 inches 0.540 inches 13.7 MM 0.088 inches 2.24 MM 0.42 lb/ft 0.84 kg/m
    1/2 inches 0.840 inches 21.3 MM 0.109 inches 2.77 MM 0.85 lb/ft 1.27 kg/m
    3/4 inches 1.050 inches 26.7 MM 0.113 inches 2.87 MM 1.13 lb/ft 1.69 kg/m
    1 inches 1.315 inches 33.4 MM 0.133 inches 3.38 MM 1.68 lb/ft 2.50 kg/m
    1 1/4 inches 1.660 inches 42.2 MM 0.140 inches 3.56 MM 2.27 lb/ft 3.39 kg/m
    1 1/2 inches 1.900 inches 48.3 MM 0.145 inches 3.68 MM 2.72 lb/ft 4.05 kg/m
    2 inches 2.375 inches 60.3 MM 0.154 inches 3.91 MM 3.65 lb/ft 5.44 kg/m
    2 1/2 inches 2.875 inches 73.0 MM 0.203 inches 5.16 MM 5.79 lb/ft 8.63 kg/m
    3 inches 3.500 inches 88.9 MM 0.216 inches 5.49 MM 7.58 lb/ft 11.29 kg/m
    3 1/2 inches 4.000 inches 101.6 MM 0.226 inches 5.74 MM 9.11 lb/ft 13.57 kg/m
    4 inches 4.500 inches 114.3 MM 0.237 inches 6.02 MM 10.79 lb/ft 16.07 kg/m
    5 inches 5.563 inches 141.3 MM 0.258 inches 6.55 MM 14.62 lb/ft 21.77 kg/m
    6 inches 6.625 inches 168.3 MM 0.280 inches 7.11 MM 18.97 lb/ft 28.26 kg/m
    8 inches 8.625 inches 219.1 MM 0.322 inches 8.18 MM 28.55 lb/ft 42.55 kg/m
    10 inches 10.750 inches 273.0 MM 0.365 inches 9.27 MM 40.48 lb/ft 60.31 kg/m
    12 inches 12.750 inches 323.8 MM 0.406 inches 10.31 MM 53.52 lb/ft 79.73 kg/m
    14 inches 14 inches 355.6 MM 0.375 inches 11.13 MM 54.57 lb/ft 94.55 kg/m
    16 inches 16 inches 406.4 MM 0.500 inches 12.70 MM 82.77 lb/ft 123.30 kg/m
    18 inches 18 inches 457.0 MM 0.562 inches 14.27 MM 104.67 lb/ft 155.80 kg/m
    20 inch 20 inch 508.0 MM 0.594 inch 15.09 MM 123.11 lb/ft 183.42 kg/m
    24 inch 24 inch 610.0 MM 0.688 inch 17.48 MM 171.29 lb/ft 255.41 kg/m
    32 inch 32 inch 813.0 MM 0.688 inch 17.48 MM 230.08 lb/ft 342.91 kg/m

    Schedule 30 Pipes Pressure Rating

    Maximum Allowable Pressure (psi) (kPa)
    NPS Outside Diameter Schedule
    (in) (in)
    (mm)
    30
    1/4 0.54
    13.7
    3/8 0.675
    17.1
    1/2 0.84
    21.3
    3/4 1.05
    26.7
    1 1.315
    33.4
    1 1/4 1.66
    42.2
    1 1/2 1.9
    48.3
    2 2.375
    60.3
    2 1/2 2.875
    73
    3 3.5
    88.9
    3 1/2 4
    102
    4 4.5
    114
    5 5.563
    141
    6 6.625
    168
    8 8.625
    219
    1420
    9791
    10 10.75
    273
    1140
    7860
    12 12.75
    324
    961
    6626
    14 14
    356
    1092
    7529
    16 16
    406
    956
    6592
    18 18
    457
    849
    5854
    20 20
    508
    919
    6337
    22 22
    559
    835
    5757
    24 24
    610
    766
    5282
    30 30
    762
    817
    5633
    32 32
    813
    766
    5282
    34 34
    864
    721
    4971
    36 36
    914
    681
    4695
    42 42
    1067
    583
    4020

    Schedule 30 Steel Pipes Size Chart

    NPS 1/2 3/4 1 2 3 4
    DN 15 20 25 32 40 50 65 80 90 100

    SCH 30 Stainless Steel Pipe Applications

    Chemical and Petrochemical Industry: SCH 30 stainless steel pipes are ideal for handling corrosive fluids and chemicals. They are used in chemical processing plants, refineries, and petrochemical facilities for transporting substances like acids and alkalis.

    Food and Beverage Industry: These pipes are preferred for their hygienic properties and corrosion resistance. They are used to convey food-grade liquids such as milk, juices, and edible oils.

    Water and Wastewater Treatment: SCH 30 stainless steel pipes are employed in water treatment plants for distributing potable water and transporting wastewater. Their durability and resistance to corrosion make them suitable for these applications.

    Pharmaceutical Industry: In pharmaceutical manufacturing, particularly in cleanroom environments, SCH 30 pipes are used for transporting pharmaceutical liquids, chemicals, and gas, ensuring sanitary conditions.

    Construction and Architecture: These pipes are used in architectural structures like bridges, building facades, and railings. Their strength and corrosion resistance make them suitable for both structural and decorative purposes.

    Oil and Gas Industry: SCH 30 stainless steel pipes are utilized in offshore platforms, pipelines, and refineries. They offer excellent resistance to corrosive environments, making them ideal for transporting oil, gas, and other hydrocarbons.

    Power Generation: Used in power plants for steam and condensate systems, SCH 30 pipes withstand high temperatures, pressure, and corrosive conditions, making them suitable for thermal and nuclear power plants.

    Automotive Industry: In the automotive sector, these pipes are found in exhaust systems, where they resist high temperatures and corrosive gas.

    Supply and Exporter

    Taiwan, Mexico, Iran, Namibia, Afghanistan, Netherlands, Nepal, Ireland, Libya, Morocco, Iran, Switzerland, Finland, Slovakia, Pakistan, Australia, Serbia, Angola, China, Philippines, Czech Republic, Belgium, Estonia, Costa Rica, Croatia, Sweden, Venezuela, Colombia, India, Belarus, Jordan, Azerbaijan, Mongolia, Vietnam, Ghana, Iraq, Algeria, Puerto Rico, New Zealand, Singapore, Indonesia, Ukraine, Israel, Mexico, Hong Kong, Bhutan, Germany, Brazil, Plan, Yemen, Malasiya, USA, Cambodia, Laos, Uganda, Tanzania, Sudan, Democratic Republic of Congo, zambia, Ethiopia, Brunei, Madagascar, Niger, Mali, Bangladesh, Bolivia, United States, Ecuador, Lebanon, Italy, South Korea, Denmark, Norway, Sri Lanka, Zimbabwe, Japan, Yemen, Oman, Portugal, Lithuania, Canada, Macau, Bahrain, Austria, Bulgaria, Spain, Kenya, United Kingdom, United Arab Emirates, Kazakhstan, Egypt, Saudi Arabia, Gambia, Argentina, Romania, Tibet, France, Chile, Gabon, South Africa, Trinidad & Tobago,Tunisia, Turkey, Nigeria, Peru, Russia, Chile, Nigeria, Hungary, Qatar, Greece, Malaysia, Kuwait, Poland, Thailand, Poland,Germany, Belgium, Italy, Turkey, Denmark and UK.

    FAQs

    Schedule 30 steel pipes are used for applications that do not require high pressure ratings. Common uses include water and gas transfer, where the pipes’ low to medium pressure rating is adequate.
    Stainless Steel Schedule 30 pipes are used in applications where the working pressure is relatively low. They are suitable for plumbing systems, irrigation, and general fluid transportation, where high-pressure capabilities are not required.
    Schedule 30 pipes have wall thicknesses ranging from 1.45 mm to 15.88 mm. Pipes with higher wall thickness and smaller diameters generally have a higher pressure rating.